伍家驹, 陈其庆, 高思远, 等. 分离绕组变压器漏感的建模方法[J]. 高电压技术, 2026,52(5):2312-2325.
WU Jiaju, CHEN Qiqing, GAO Siyuan, et al. 分离绕组变压器漏感的建模方法[J]. 2026, 52(5): 2312-2325.
伍家驹, 陈其庆, 高思远, 等. 分离绕组变压器漏感的建模方法[J]. 高电压技术, 2026,52(5):2312-2325. DOI: 10.13336/j.1003-6520.hve.20251252.
WU Jiaju, CHEN Qiqing, GAO Siyuan, et al. 分离绕组变压器漏感的建模方法[J]. 2026, 52(5): 2312-2325. DOI: 10.13336/j.1003-6520.hve.20251252.
为提高分离绕组变压器漏感量的计算精度,提出了一种兼顾铁芯和绕组径向磁场的漏感分析方法。首先,用实验唯象揭示了铁芯漏磁能的存在,从B-H曲线求出交流有效磁导率,并借助典型软铁求出硅钢片主磁感线与铁芯界面法线的夹角,推算出铁芯的径向漏磁能及其对应的漏感。然后,用长径比表达绕组轴、径向漏磁能密度曲线,通过研判磁能定积分的上下限确定绕组轴向的两对称虚拟端面,以算出与绕组轴向、径向磁场对应的漏磁能及其漏感。最后,用4D技术渲染铁芯漏感和绕组漏感的数值分布,为操控漏感建模提供取值范围。实际工况下的漏感测算和LCR电桥测量均检验了所控漏感的误差小于4%,并以漏感取代LC滤波器中的电感器展现了该建模方法的有效性。该研究可为操控分离绕组变压器漏感和测算绕组本体径向磁场提供参考。
To improve the calculation accuracy of leakage inductance in separated winding transformers
a leakage inductance analysis method that accounts for both the core and winding radial magnetic fields was proposed. Firstly
the existence of magnetic leakage energy in the iron core was revealed by experiments. The alternating effective magnetic permeability was obtained from the B-H curve; meanwhile
by utilizing typical soft iron
the angle between the main magnetic flux lines of the silicon steel sheet and the normal to the iron core interface was determined
and the radial leakage magnetic energy of the iron core along with its corresponding leakage inductance were calculated. Then
the length-to-diameter ratio was used to express the leakage magnetic energy density curves of the winding shaft and radial directions. By analyzing the upper and lower limits of the magnetic energy definite integral
the two symmetrical virtual end faces of the winding axis were determined
which was used to select and discard the leakage magnetic energy and leakage inductance corresponding to the winding shaft and radial magnetic fields. Finally
the numerical distribution of core leakage inductance and winding leakage inductance was rendered using 4D technology to provide a range of values for modeling control leakage sensation. The leakage inductance measurement under actual working conditions and the LCR bridge measurement both verified that the error of the controlled leakage inductance was less than 4%
and the effectiveness of this modeling method was demonstrated by replacing the inductor in the LC filter with leakage inductance. This research can provide a reference for manipulating the leakage inductance of separated winding transformers and calculating the radial magnetic field of the winding body.