触头表面状态直接影响真空断路器的开断性能及其运行可靠性。由于真空灭弧室通常被密封于固体绝缘材料中,现有的触头状态评估方法大多依赖拆解操作,难以实现工程现场的无损测量。针对上述问题,该文提出一种基于直流电压下合闸过程的场致发射电流无损测量方法,可在无需拆卸真空灭弧室的前提下实现对触头表面微观状况的定量评估。首先系统分析了热-场致发射理论,建立了适用于不同测量场景下的数学模型,对比了交流静开距与直流动开距两种测量方法的适用性与测量精度。随后,结合Fowler-Nordheim和Murphy-Good两种理论,分别构建场致发射电流特征图谱,提出了相应的触头场致增强系数与有效发射面积提取方法。在容性投切实验中,将所提出的新型测量系统与综合实验平台进行集成,通过逐次加载高频涌流并监测场致发射特性,实现了对触头表面烧蚀过程的定量追踪。实验结果表明,该方法不仅简化了测量流程,显著提高了工程适用性,同时具备良好的数据一致性和理论可解释性,可为真空断路器在线状态评估与寿命预测提供有效支撑。
The contact surface condition directly affects the breaking performance and operational reliability of vacuum circuit breakers. Since vacuum interrupters are typically sealed within solid insulating materials
existing contact assessment methods mostly rely on disassembly procedures
making it difficult to achieve non-destructive measurement on-site in engineering. To address this issue
this paper proposes a non-destructive measurement method based on field emission current during the closing process under DC voltage
enabling quantitative evaluation of contact surface microtopography without disassembling the vacuum interrupter. First
this paper systematically analyzes thermionic-field emission theory
establishes mathematical models suitable for different measurement scenarios
and compares the applicability and measurement accuracy of two methods
namely
AC static contact gap and DC dynamic contact gap measurements. Subsequently
by integrating Fowler-Nordheim and Murphy-Good theories
characteristic field emission current profiles are constructed
and corresponding extraction methods for the field enhancement factor and effective emission area of contacts are proposed. In capacitive switching experiments
the proposed measurement system is integrated with a comprehensive test platform. By sequentially applying high-frequency inrush currents and monitoring field emission characteristics
quantitative tracking of contact surface erosion is achieved. The experimental results demonstrate that this method not only simplifies the measurement process and significantly improves engineering applicability
but also exhibits strong data consistency and theoretical interpretability. The method can provide effective support for online condition assessment and lifespan prediction of vacuum circuit breakers.