多元混合绝缘油长油隙下的雷电冲击放电特性是评估其绝缘性能的重要参数,对变压器结构优化设计具有重要指导意义,是其能否在高电压等级、大容量变压器中安全可靠应用的关键依据。该文开展了25~105 mm间隙下多元混合绝缘油的雷电冲击击穿特性研究,研究了多元混合绝缘油的放电发展速度、流注发展形貌、放电击穿电压及威布尔分布。结果表明:由于多元混合绝缘油中酯类绝缘油流注存在加速效应,其长油隙下的雷电冲击放电发展速度比矿物油更快;短间隙条件下,多元混合绝缘正负极性流注形貌分别呈现多分支细丝状和细丝状,长间隙条件下,多元混合绝缘油正负极性流注形貌分别呈现灌木丛状和树枝状,在放电发展过程中存在明显的发光和二次流注现象;多元混合绝缘油正极性雷电冲击击穿电压略低于矿物油,显著高于酯类绝缘油,与二元混合绝缘油和三元混合绝缘油相差不大,多元混合绝缘油负极性雷电冲击击穿电压比现有混合绝缘油高16%~50%,在85~105 mm间隙下与矿物油基本相当。
The lightning impulse breakdown properties of multi-component mixed insulating oil under long oil gaps are crucial parameters for evaluating its insulation performance. These characteristics provide valuable guidance for optimizing transformer structure design and serve as a key foundation for ensuring the safe and reliable operation of high-voltage and large-capacity transformers. This study investigates the lightning impulse discharge characteristics of long oil gaps in multi-component mixed insulating oil
focusing on the discharge point development speed
streamer development morphology
breakdown voltage
and Weibull distribution under oil gap lengths ranging from 25 mm to 105 mm. The findings reveal that
due to the acceleration effect of ester insulating oil flow within the multi-component mixture
the development speed of lightning impulse discharge under long oil gaps is significantly faster than that of mineral oil. Under short-gap conditions
the discharge point development speed of multi-component mixed insulating oil is also higher for both positive and negative electrodes compared to mineral oil. The streamer morphologies under positive and negative polarities exhibit multi-branched filaments and single filaments
respectively. For long-gap conditions
the streamer morphologies are bush-like for positive polarity and tree-like for negative polarity. In terms of breakdown voltage
the positive polarity lightning impulse breakdown voltage of multi-component mixed insulating oil is slightly lower than that of mineral oil but significantly higher than that of ester insulating oil. Furthermore
it is comparable to binary and ternary mixed insulating oils. The negative polarity lightning impulse breakdown voltage of multi-component mixed insulating oil is 16%~50% higher than that of existing mixed insulating oils. Specifically
it aligns closely with mineral oil at gaps between 85 mm and 105 mm.