现有低电流应力高增益双向变换器普遍存在高压侧电流脉动、器件数量多且变换效率较低等缺点,难以满足混合储能系统的性能要求。为此,提出了一种高压侧电流近似零纹波且少器件的零电压开关(zero-voltage- switching
ZVS)交错并联高增益双向变换器。所提变换器可通过将Buck/Boost变换器和耦合电感Cuk双向变换器的低压侧并联、高压侧串联而得到。当占空比满足D2=1/(2−D1)的约束关系时,所提变换器可以实现低压侧电感电流的自动均分,且电压增益为2/(1−D1),开关管的电压应力等于或接近高压侧电压的一半。所提变换器工作在三角形电流模式下,通过合理的电感量设计,可以在全工作范围内实现所有开关管的ZVS开通和高压侧电流零纹波,进而能移除高压侧滤波器,并减小体积和损耗,改善变换效率。全面分析了所提变换器的工作原理、稳态特性、零电流纹波和软开关条件、控制策略和参数设计方法,并通过一台低压侧电压40~56 V、高压侧电压400 V、最大功率500 W、最低开关频率50 kHz的样机实验验证了理论分析的正确性。样机的实测最高和最低效率分别为97.6%和94.2%。
Existing low-current-stress high-gain bidirectional converters generally suffer from drawbacks such as discontinuous high-voltage-side (HVS) current
excessive component count
and low conversion efficiency
making them unsuitable for hybrid energy storage systems. To address these issues
this paper proposes an interleaved high-gain bidirectional converter
featuring near-zero current ripple on HVS
zero-voltage-switching (ZVS) operation and reduced component count. The proposed topology is derived by parallel-connecting the low-voltage sides (LVSs) of a Buck/Boost converter and a coupled-inductor Cuk bidirectional converter while series-connecting their HVSs. When the duty cycle satisfies the constraint D2=1/(2−D1)
the converter achieves automatic current sharing in the LVS inductors and achieves a voltage gain of 2/(1−D1)
with the voltage stress on switches equal to or approaching half of the HVS voltage. Operating in triangular current mode
the converter enables ZVS turn-on for all switches across the entire operating range and achieves zero ripple current on HVS through optimized inductance design; therefore
the need for an HVS filter can be eliminated
the volume and losses can be reduced
and the conversion efficiency can be improved. Comprehensive analyses are presented on the operating principles
steady-state characteristics
zero-current-ripple conditions
soft-switching criteria
control strategy
and parameter design methodology. A 500 W prototype with an LVS voltage range of 40~56 V
HVS output of 400 V
and minimum switching frequency of 50 kHz validates the theoretical analysis. Experimental results demonstrate peak and minimum efficiencies of 97.6% and 94.2%
respectively.