To address the issues of the lack of an analytical model for oscillation centers and the migration of oscillation centers in power systems with different forms of DC integration after being disturbed
this paper proposes a non-autonomous admittance substitution method
based on an impedance perspective
to describe the impact of multiple DC integrations on the AC grid. The method begins by considering the operational characteristics of DC systems
making approximate assumptions from an impedance perspective
and constructing an analytical model for oscillation centers in a system with a single DC integration. This transforms the impact of DC integration into an effect on the impedance of the system's tie-lines. Next
impedance circle diagrams are used to analyze and conclude that the oscillation center will shift toward the receiving end after DC integration. Subsequently
based on the single DC integration model
parallel models for multiple DC integrations and models for DC systems within coherent groups are constructed. The patterns of oscillation center migration are analyzed on the basis of variations in system parameters. Finally
the correctness of the equivalent method and the patterns of oscillation center migration after DC integration are validated through simulation examples using an improved hybrid AC-DC CSEE-RAS79 node system.